Honeywell R78 Series Flame Amplifiers Model Selection Guide
- Flame signal strength ranges from 0.0 to 5.0 VDC, with test jacks to measure amplifier flame signal voltage
- Color-coded labels identify flame detection type. Green=Rectification, Red=Infrared, Purple=Ultraviolet
- Dynamic Ampli-Check circuitry tests the flame amplifier during burner operation.
- Dynamic Self-Check circuitry tests electronic components in the flame detection system 10 to 12 times per minute.
- Note: R7849A flame detectors should be used only on burners that cycle on and off at least once every 24 hours. Appliances with burners that remain on for 24 hours or longer should use ultraviolet flame detection systems (C7012E/F detector and R7847C amplifier, or C7076A detector and R7886A amplifier.)
- See the Honeywell R78 flame amplifiers page for further specifications
Models Available to Buy | ||||
If the model you need isn't listed here, call us. | ||||
Image | Flame Failure Response Time |
Self- Checking |
Compatible Flame Sensors | Model |
Rectification-Type Flame Signal Amplifiers. Color Code=Green | ||||
0.8 or 1.0 Seconds | Standard | Gas: Rectifying flame rods C7004/7005/7007/7008/7009, Q179 | R7847A1025 | |
0.8 or 1.0 Seconds | Standard | Gas: Rectifying flame rods C7004/7005/7007/7008/7009, Q179 (Leadwire runs >50 Ft) | R7847A1074 | |
2.0 or 3.0 Seconds | Standard | Gas: Rectifying flame rods C7004/7005/7007/7008/7009,
Q179 Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012A, C |
R7847A1033 | |
2.0 or 3.0 Seconds | Standard | Gas: Rectifying flame rods C7004/7005/7007/7008/7009,
Q179 (Leadwire runs >50 Ft) Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012A, C |
R7847A1082 | |
0.8 or 1.0 Seconds | Ampli-Check | Gas: Rectifying flame rods C7004/7005/7007/7008/7009, Q179 | R7847B1023 | |
0.8 or 1.0 Seconds | Ampli-Check | Gas: Rectifying flame rods C7004/7005/7007/7008/7009, Q179 (Leadwire runs >50 Ft) | R7847B1064 | |
2.0 or 3.0 Seconds | Ampli-Check | Gas: Rectifying flame rods C7004/7005/7007/7008/7009,
Q179 Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012A, C |
R7847B1031 | |
3.0 Seconds | Dynamic | C7024E, F Flame Detectors and RM7824 Relay Modules | R7824C1002 | |
2.0 or 3.0 Seconds | Dynamic | Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012E, F | R7847C1005 | |
Infrared-Type Flame Signal Amplifiers. Color Code=Red | ||||
2.0 or 3.0 Seconds | Standard | Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015 | R7848A1008 | |
2.0 or 3.0 Seconds | Ampli-Check | Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015 | R7848B1006 | |
Ultraviolet-Type Flame Signal Amplifiers. Color Code=Purple | ||||
|
0.8 or 1.0 Second | Standard | Gas or Oil: Minipeeper C7027A, C7035A, C7044 | R7849A1015 |
2.0 or 3.0 Seconds | Standard | Gas or Oil: Minipeeper C7027A, C7035A, C7044 | R7849A1023 | |
0.8 or 1.0 Second | Ampli-Check | Gas or Oil: Minipeeper C7027A, C7035A, C7044 | R7849B1013 | |
2.0 or 3.0 Seconds | Ampli-Check | Gas or Oil: Minipeeper C7027A, C7035A, C7044 | R7849B1021 | |
0.8 or 1.0 Second | Dynamic | Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061 | R7861A1034 | |
2.0 or 3.0 Seconds | Dynamic | Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061 | R7861A1026 |