Hoffer 3A Sanitary Turbine Flowmeters for Liquid Applications

The Hoffer 3A sanitary turbine flowmeter is designed measuring process liquids in clean applications. For optimum performance, this flowmeter requires a minimum of 10 pipe diameters upstream and 5 pipe diameters downstream. This turbine flowmeter must be installed with the pickup coil pointing downward to ensure proper cleanability per the 3A sanitary standard.

 

  • Meets 3A Sanitary Standard 28-03 for measuring process liquids
  • Available in sizes from 1/4" to 3" with Tri-Clamp™ fittings
  • For linear flow ranges 0.35 GPM to 650 GPM
  • 316/316L dual rated stainless steel construction with hard carbon composite bearings, 17.4 PH stainless rotor, and 15.7 MO PH stainless retaining ring
  • Accuracy and linearity: ± 0.5% reading or better
  • Process temperature ranges -40° to 450°F with standard magnetic pickup coil. Good to 850° with high temperature magnetic pickup coil

 

Tri-Clamp SizeFlowmeter SizeStd Flow RangeNominal
Pulses/Gallon
Nominal
Max Frequency
LengthModel
0.75"0.25"0.35 to 3.5 GPM15000900 Hz3.56"HO3A-3/4x1/4A-0.35-3.5-
0.75"0.375"0.75 to 7 GPM89001100 Hz3.56"HO3A-3/4x3/8A-0.75-7-
0.75"0.5"1.25 to 9.5 GPM5800900 Hz3.56"HO3A-3/4x1/2A-1.25-9.5-
0.75"0.625"1.75 to 16 GPM52001400 Hz3.56"HO3A-3/4x5/8A-1.75-16-
1.5"0.25"0.35 to 3.5 GPM15000900 Hz3.56"HO3A-1-1/2x1/4A-0.35-3.5-
1.5"0.375"0.75 to 7 GPM89001100 Hz3.56"HO3A-1-1/2x3/8A-0.75-7-
1.5"0.5"1.25 to 9.5 GPM5800900 Hz3.56"HO3A-1-1/2x1/2A-1.25-9.5-
1.5"0.625"1.75 to 16 GPM52001400 Hz3.56"HO3A-1-1/2x5/8A-1.75-16-
1.5"0.75"2.5 to 29 GPM22001065 Hz3.25"HO3A-1-1/2x3/4A-2.5-29-
1.5"1"4 to 60 GPM660660 Hz3.56"HO3A-1-1/2x1A-4-60-
1.5"1.25"6 to 93 GPM400620 Hz4.59"HO3A-1-1/2x1-1/4A-6-93-
1.5"1.5"8 to 130 GPM230500 Hz4.59"HO3A-1-1/2x1-1/2A-8-130-
2"2"15 to 225 GPM120450 Hz6.06"HO3A-2x2A-15-225-
3"2.5"25 to 400 GPM97650 Hz10"HO3A-3x2-1/2A-25-400-
4"3"40 to 650 GPM45500 Hz10"HO3A-4x3A-40-650-
Bearing TypeHard Carbon Composite Sleeve M-199 Grade (for Media pH 6 and Above)
Hard Carbon Composite Sleeve M-100 Grade (for Media pH <6)
C9
C1
Pickup CoilsOne Magnetic Coil1M
Coil Enclosure1" MNPT Riser, Welded to Body, Rated Class I, Groups C, DX
End FittingTri-Clover Sanitary End FittingTRI


Catalogue Section: Flow Measurement Instruments Catalog Section: Flow Measurement Instruments
Complete a Hoffer Turbine Flowmeters application datasheet Hoffer Flow Controls Turbine Flowmeter Application Datasheet Faxback Form
Hoffer Turbine Flowmeters Engineering Guide for Liquid Applications Hoffer Turbine Flowmeters Engineering Guide for Liquid Applications
Hoffer 3A Sanitary Turbine Flowmeters Specification Datasheet Hoffer 3A Sanitary Turbine Flowmeters Specification Datasheet
Hoffer 3A Sanitary Turbine Flowmeters User Manual Hoffer 3A Sanitary Turbine Flowmeters User Manual
Hoffer Turbine Flowmeters User Manual Hoffer Turbine Flowmeters General User Manual