Choosing the Right Honeywell Stripchart Recorder

Honeywell Honeywell DPR100C 4" Stripchart RecorderHoneywell DPR100D 4" Stripchart Recorder
DPR100 C/D 4" Stripchart Recorders
Honeywell DPR180 7" Stripchart Recorder
DPR180 7" Stripchart Recorders
Honeywell DPR250 10" Stripchart Recorder
DPR250 10" Stripchart Recorders
Accuracy 0.10% 0.5% with Field Calibration 0.5% with Field Calibration
Universal Inputs 1, 2, 3 or 6 4 to 24 4 to 64
Input Features Carbon Potential, Cu. 10Ω RTD Charactizer
<2 (50 pts), Isolation, Relative Humidity
Carbon Potential, Cu 10Ω RTD Charactizer
<2 (50 pts), Isolation, Relative Humidity
Carbon Potential, Cu. 10Ω RTD Charactizer
<2 (50 pts), Isolation, Relative Humidity
Sample Rate 0.64 Seconds (6) 1.3 Seconds (24) 3.3 Seconds (64)
Digital Inputs 2 or 4 36 48
Auxiliary Outputs Up to Two 4-20mA Outputs, Universal Communications Output Up to Eight 4-20 mA Outputs, Retransmitting PV, Math Calculations or Program Profile
Alarms
(Capabilities)
12 Alarm Setpoints, Assignable to any Input, Math Result or Communication Signal Up to 48 Setpoints, Assignable to Analog Inputs, Math, Communications or Program Profile Up to 64 Alarm Setpoints Assignable to Any Channel and Output Relay
Alarms (Relays) Up to 12 Alarm Relays, Assignable to Alarms or Recorder Events Up to 36 Alarm Relays, Assignable to Alarms or Recorder Events Up to 48 Alarm Relays, Assignable to Alarms or Recorder Events
Communications Ethernet Interface, Modbus/ASCII 422/485 RTU, ASCII RS-232 Ethernet Interface, Modbus/ASCII 422/485 RTU, ASCII RS-232 Ethernet Interface, Modbus/ASCII 422/485 RTU, ASCII RS-232
Math Functions Basic Math (+,-,x,/), Square Root and Differential, Optional: Fo Sterilization, Mass Flow, Energy Consumption, Averages, Min./Max., Timers, Carbon Potential, RH, Steam Flow Totalization, Vacuum Pressure and Totalization Basic Math (+,-,x,/), Square Root, Fo Sterilization, Totalization, Mass Flow, Energy Consumption, Averages, Min./Max., Timers, Carbon Potential and RH Basic Math (+,-,x,/), Square Root, Fo Sterilization, Totalization, Mass Flow, Energy Consumption, Averages, Timers, Counters and Min./Max.
Added
Functionality
Event Precursor Mode, 6 Totalizers with Math Event Precursor Mode; Logic Programming, PCMCIA Data Storage Option, 24 Totalizers with Math Event Precursor Mode, PCMCIA Data Storage Option, Up to 48 Logic Inputs (Groups of 6) to Trigger Speed Change, Digital Printout Message, Math Result, Range or Relay Output, 32 Totalizers with Math
Front Panel IP54 IP55 IP55
Power Features 24 or 48VAC/DC, 75mA Transmitter Power, 85-264VAC/DC Special 24 or 48VAC/DC, 85-264VAC/DC Special 24 or 48VAC/DC, 85-264VAC/DC
Prices Start At Call us Call us Call us
Approvals Approvals: CE, UL, CSA Approvals: CE, CSA Approvals: CE, CSA