Honeywell DR4500 12" Classic Circular Recorders
Honeywell's DR4500 Classic 12" circular chart recorder is ideal in applications where measured variables must be documented on a single chart to meet industry requirements. Its digital displays show PV, setpoint, output, deviations, dry bulb temperature, totalization, or engineering units.
With two control loops, improved setpoint programming, and calculations for BTU and mass flow, the Classic is the perfect fit for most applications.
- Accuracy to ±0.15% Span
- Up to 2 Inputs
- Fully User Configurable
- One or Two Control Loops: Full PID Control, Full Range of Outputs
- Totalization and Setpoint Programming Options
- Choose from 5,000 Preprinted Charts
- Digital Communications Over RS485 Modbus RTU Interface
- Compare Features of Honeywell Circular Chart Recorders
Use this table to find the right model for your application. Click the model number to order in our secure online store. If the model you need isn't available in our online store, use the [Get a Quote] button above to request current pricing and availability.
Not all options are available on all Classic models. Please refer to the specification datasheet under Product Literature for complete details.
Description | Model Number | |
---|---|---|
Single Pen Classic 12" Circular Chart Recorder Dual Pen Classic 12" Circular Chart Recorder |
DR45A1- DR45A2- | |
Table I — Inputs | ||
Channel 1 Input | T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic 0-10 VDC | 1 _ _ _- 3 _ _ _- |
Channel 2 Input | None T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic 0-10 VDC | _ 000- _ 100- _ 300- |
Table II — External Outputs | ||
Output #1 | None Control Output #1 | 0 _- 1 _- |
Output #2 | None Control Output #2 | _ 0- _ 1- |
Table III — Interface | ||
External Interface | None Auxiliary 4-20 mA Output RS485 Modbus RTU Communications RS485 Modbus RTU and 4-20 mA Outputs | 0 _ _- 1 _ _- 3 _ _- 4 _ _- |
Pens | Standard Pen | _ 0 _- |
Alarms and Digital Inputs | None Two Alarms, Two Digital Inputs One Alarm, One Timer Output, Two Digital Inputs | _ _ 0- _ _ 1- _ _ 4- |
Table IV — Software Options | None Totalization on Input #1 Totalization on Inputs #1, #2 | 0- A- E- |
Table V — Options | ||
Door and Window Materials | Gray Door with Glass Windows Gray Door with Acrylic Window Blue Door with Glass Window Blue Door with Acrylic Window Stainless Steel Door with Glass Window Stainless Steel Door with Acrylic Window NEMA 4X Door with Glass Window NEMA 4X Door with Acrylic Window | 0 _ _ _ _ _-0 1 _ _ _ _ _-0 5 _ _ _ _ _-0 6 _ _ _ _ _-0 2 _ _ _ _ _-0 3 _ _ _ _ _-0 P _ _ _ _ _-0 R _ _ _ _ _-0 |
Latch and Lock | Standard Door Latch Keyed Latch (Standard on AH/AP/AS) Door Lock with Key | _ 0 _ _ _ _-0 _ A _ _ _ _-0 _ K _ _ _ _-0 |
Security | None Configuration Lockout and Chart Plate Seal Configuration Lockout, Chart Plate Seal, Chart Illumination Chart Illumination | _ _ 0 _ _ _-0 _ _ L _ _ _-0 _ _ M _ _ _-0 _ _ N _ _ _-0 |
Agency Approvals | None CE CE, UL, CSA CE, FM Approval CE, UL, CSA, and FM Approval UL, CSA FM Approved Class I, Div 2, Groups A-D UL, CSA, and FM Approval | _ _ _ 0 _ _-0 _ _ _ K _ _-0 _ _ _ L _ _-0 _ _ _ M _ _-0 _ _ _ N _ _-0 _ _ _ P _ _-0 _ _ _ R _ _-0 _ _ _ U _ _-0 |
Documents and Tags | None Customer ID Tag (30 Characters Max) F3391 Certificate of Conformance F3399 Calibration Test Report F3391 Certificate of Conformance and ID Tag F3399 Calibration Test Report and ID Tag | _ _ _ _ 0 E-0 _ _ _ _ T E-0 _ _ _ _ B E-0 _ _ _ _ C E-0 _ _ _ _ D E-0 _ _ _ _ E E-0 |