Honeywell DR4500 12" Classic Circular Recorders

Honeywell's DR4500 Classic 12" circular chart recorder is ideal in applications where measured variables must be documented on a single chart to meet industry requirements. Its digital displays show PV, setpoint, output, deviations, dry bulb temperature, totalization, or engineering units.

With two control loops, improved setpoint programming, and calculations for BTU and mass flow, the Classic is the perfect fit for most applications.

 

  • Accuracy to ±0.15% Span
  • Up to 2 Inputs
  • Fully User Configurable
  • One or Two Control Loops: Full PID Control, Full Range of Outputs
  • Totalization and Setpoint Programming Options
  • Choose from 5,000 Preprinted Charts
  • Digital Communications Over RS485 Modbus RTU Interface
  • Compare Features of Honeywell Circular Chart Recorders

 

Use this table to find the right model for your application. Click the model number to order in our secure online store. If the model you need isn't available in our online store, use the [Get a Quote] button above to request current pricing and availability.

Not all options are available on all Classic models. Please refer to the specification datasheet under Product Literature for complete details.

 
Description
Model
Number
Single Pen Classic 12" Circular Chart Recorder
Dual Pen Classic 12" Circular Chart Recorder
DR45A1-
DR45A2-
Table I — Inputs
Channel 1
Input
T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic
0-10 VDC
1 _ _ _-
3 _ _ _-
Channel 2
Input
None
T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic
0-10 VDC
_ 000-
_ 100-
_ 300-
Table II — External Outputs
Output #1None
Control Output #1
0 _-
1 _-
Output #2None
Control Output #2
_ 0-
_ 1-
Table III — Interface
External
Interface
None
Auxiliary 4-20 mA Output
RS485 Modbus RTU Communications
RS485 Modbus RTU and 4-20 mA Outputs
0 _ _-
1 _ _-
3 _ _-
4 _ _-
PensStandard Pen_ 0 _-
Alarms and
Digital Inputs
None
Two Alarms, Two Digital Inputs
One Alarm, One Timer Output, Two Digital Inputs
_ _ 0-
_ _ 1-
_ _ 4-
Table IV —
Software Options
None
Totalization on Input #1
Totalization on Inputs #1, #2
0-
A-
E-
Table V — Options
Door and
Window
Materials
Gray Door with Glass Windows
Gray Door with Acrylic Window
Blue Door with Glass Window
Blue Door with Acrylic Window
Stainless Steel Door with Glass Window
Stainless Steel Door with Acrylic Window
NEMA 4X Door with Glass Window
NEMA 4X Door with Acrylic Window
0 _ _ _ _ _-0
1 _ _ _ _ _-0
5 _ _ _ _ _-0
6 _ _ _ _ _-0
2 _ _ _ _ _-0
3 _ _ _ _ _-0
P _ _ _ _ _-0
R _ _ _ _ _-0
Latch and LockStandard Door Latch
Keyed Latch (Standard on AH/AP/AS)
Door Lock with Key
_ 0 _ _ _ _-0
_ A _ _ _ _-0
_ K _ _ _ _-0
SecurityNone
Configuration Lockout and Chart Plate Seal
Configuration Lockout, Chart Plate Seal, Chart Illumination
Chart Illumination
_ _ 0 _ _ _-0
_ _ L _ _ _-0
_ _ M _ _ _-0
_ _ N _ _ _-0
Agency
Approvals
None
CE
CE, UL, CSA
CE, FM Approval
CE, UL, CSA, and FM Approval
UL, CSA
FM Approved Class I, Div 2, Groups A-D
UL, CSA, and FM Approval
_ _ _ 0 _ _-0
_ _ _ K _ _-0
_ _ _ L _ _-0
_ _ _ M _ _-0
_ _ _ N _ _-0
_ _ _ P _ _-0
_ _ _ R _ _-0
_ _ _ U _ _-0
Documents
and Tags
None
Customer ID Tag (30 Characters Max)
F3391 Certificate of Conformance
F3399 Calibration Test Report
F3391 Certificate of Conformance and ID Tag
F3399 Calibration Test Report and ID Tag
_ _ _ _ 0 E-0
_ _ _ _ T E-0
_ _ _ _ B E-0
_ _ _ _ C E-0
_ _ _ _ D E-0
_ _ _ _ E E-0

 

 

Catalogue Section: Recorders and Data Acquisition Catalog Section: Recorders and Data Acquisition
Honeywell DR4500 Classic 12" Circular Chart Recorder Brochure Honeywell DR4500 Classic 12" Circular Chart Recorder Brochure
Honeywell DR4500A Classic 12" Circular Chart Recorder Specification Datasheet Honeywell DR4500A Classic 12" Circular Chart Recorder Specification Datasheet
Honeywell DR4500A Classic Recorder User Manual Honeywell DR4500A Classic Recorder User Manual
Honeywell DR4500 Classic Circular Chart Recorder Configuration Prompt Card Honeywell DR4500 Classic Parameter Configuration Prompt Card
DR4500 Classic parameter worksheet Honeywell DR4500 Classic Parameter Configuration Worksheet — Keep One for Your Records
Honeywell DR4500 Modbus RTU Serial Communications Interface Manual Honeywell Modbus RTU Serial Communications Interface Manual
How to replace a DR4500 latch and lock assembly Upgrade/Replacement: DR4500 Latch and Lock Assembly
How to replace a DR4500 pen arm assembly Upgrade/Replacement: DR4500 Pen Arm Assembly Kit
How to replace a DR4500 chart hub kit Upgrade/Replacement: DR4500 Chart Hub Kit