Honeywell DR4500 Truline 12" Circular Recorders

With more than 20 years of proven reliability, the industry standard Honeywell DR4500 Truline circular chart recorder gives you the exact data you want, written  on a chart that's drawn at the same time it records your data.

There's a Truline model that's suited for your specific industry: food, water and wastewater treatment, pharmaceutical, dairy, environmental testing, and even metal-working. Even the FDA agrees: Truline AH, AS, and AP models comply with 3A sanitary standards for use as pastuerization flow recorder/controllers, and meet the Grade "A" Pastuerized Milk ordinance.

 

 

Use this table to find the right model for your application. Click the model number to order in our secure online store. If the model you need isn't available in our online store, use the [Get a Quote] button above to request current pricing and availability.

Not all options are available on all Truline models. Please refer to the appropriate specification datasheet under Product Literature for complete details.

 
Description
Model
Number
Truline 12"
Circular Chart
Recorder
Standard Model
Relay Expansion Model
Flow Recorder
HTST (High Temperature/Short Time) Model
Pasteurization Flow Recorder
Safety Thermal Limit Recorder
DR45AT-
DR45AR-
DR45AW-
DR45AH-
DR45AP-
DR45AS-
Table I — Inputs
Channel 1
Input
T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic
0-10 VDC
1 _ _ _-
3 _ _ _-
Channel 2
Input
None
T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic
0-10 VDC
_ 0 _ _-
_ 1 _ _-
_ 3 _ _-
Channel 3
Input
None
T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic
0-10 VDC
_ _ 0 _-
_ _ 1 _-
_ _ 3 _-
Channel 4
Input
None
T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radimatic
0-10 VDC
_ _ _ 0-
_ _ _ 1-
_ _ _ 3-
Table II — External Outputs
Output #1None
Control Output #1 (for DR45AH, DR45AP)
Control Output #1
Pulse Output
0 _-
1 _-
4 _-
5 _-
Output #2None
Control Output #2 (for DR45AP)
Control Output #2
_ 0-
_ 1-
_ 4-
Table III — Interface
External
Interface
None
Auxiliary 4-20 mA Output
RS485 Modbus RTU Communications
RS485 Modbus RTU and 4-20 mA Outputs
0 _ _-
1 _ _-
3 _ _-
4 _ _-
PensTruline High Speed Pen (Black Tip on Stylus End)
Abrasion-Resistant Pen (White Tip on Stylus End)
_ 0 _-
_ 1 _-
Alarms and
Digital Inputs
None
Two Alarms, Two Digital Inputs
Four Alarms, Two Digital Inputs
Six Alarms, Two Digital Inputs
One Alarm, One Timer Output, Two Digital Inputs
_ _ 0-
_ _ 1-
_ _ 2-
_ _ 3-
_ _ 4-
Table IV —
Software Options
None
Totalization on Input #1
Totalization on Inputs #1, #2
Totalization on All Four Inputs
FO Sterilization Calculation
Math
Totalization (IN#1) plus Math
Totalization (IN#1,#2) plus Math
Totalization on All Inputs plus Math
0-
A-
E-
H-
F-
B-
K-
L-
M-
Table V — Options
Door and
Window
Materials
Gray Door with Glass Windows
Gray Door with Acrylic Window
Blue Door with Glass Window
Blue Door with Acrylic Window
Stainless Steel Door with Glass Window
Stainless Steel Door with Acrylic Window
NEMA 4X Door with Glass Window
NEMA 4X Door with Acrylic Window
NEMA 4X Door, HTST, Divert Lights (AH/AP/AS Only)
0 _ _ _ _ _-0
1 _ _ _ _ _-0
5 _ _ _ _ _-0
6 _ _ _ _ _-0
2 _ _ _ _ _-0
3 _ _ _ _ _-0
P _ _ _ _ _-0
R _ _ _ _ _-0
S _ _ _ _ _-0
Latch and LockStandard Door Latch
Keyed Latch (Standard on AH/AP/AS)
Door Lock with Key
_ 0 _ _ _ _-0
_ A _ _ _ _-0
_ K _ _ _ _-0
SecurityNone
Configuration Lockout and Chart Plate Seal
Configuration Lockout, Chart Plate Seal, Chart Illumination
Chart Illumination
_ _ 0 _ _ _-0
_ _ L _ _ _-0
_ _ M _ _ _-0
_ _ N _ _ _-0
Agency
Approvals
None
CE
CE, UL, CSA
CE, FM Approval
CE, UL, CSA, and FM Approval
UL, CSA
FM Approved Class I, Div 2, Groups A-D
UL, CSA, and FM Approval
_ _ _ 0 _ _-0
_ _ _ K _ _-0
_ _ _ L _ _-0
_ _ _ M _ _-0
_ _ _ N _ _-0
_ _ _ P _ _-0
_ _ _ R _ _-0
_ _ _ U _ _-0
Documents
and Tags
None
Customer ID Tag (30 Characters Max)
F3391 Certificate of Conformance
F3399 Calibration Test Report
F3391 Certificate of Conformance and ID Tag
F3399 Calibration Test Report and ID Tag
_ _ _ _ 0 E-0
_ _ _ _ T E-0
_ _ _ _ B E-0
_ _ _ _ C E-0
_ _ _ _ D E-0
_ _ _ _ E E-0

Catalogue Section: Recorders and Data Acquisition Catalog Section: Recorders and Data Acquisition
Honeywell DR4500A Truline 12-inch Circular Chart Recorder Short Brochure Honeywell DR4500 Truline 12" Circular Chart Recorder Brochure
Honeywell DR4500A Truline 12-inch Circular Chart Recorder Specification Datasheet Honeywell DR4500A Truline 12" Circular Chart Recorder Specification Datasheet
Honeywell DR45AW Truline Open Channel Flow Recorder Specification Datasheet Honeywell DR45AW Truline Open Channel Flow Recorder Specification Datasheet
Honeywell DR45AR Truline 6-Relay Expansion Recorder Specification Datasheet Honeywell DR45AR Truline 6-Relay Expansion Recorder Specification Datasheet
Honeywell DR45AP Truline HTST-Pasteurization Flow Recorder Specification Datasheet Honeywell DR45AP Truline HTST/Pasteurization Flow Recorder Specification Datasheet
Honeywell DR4500 Truline Parameter Configuration Worksheet Honeywell DR4500 Truline Parameter Configuration Worksheet — Print and Keep for Your Records
Honeywell DR4500 Truline Parameter Configuration Worksheet Honeywell DR4500 Truline Configuration Prompt Card
Honeywell DR4500A Truline Recorder User Manual Honeywell DR4500A Truline Recorder User Manual
Honeywell DR45AH-AP-HTST Addendum to Truline Product Manual Addendum to Honeywell Truline Product Manual for DR45AH/AP/HTST Model Recorders
Honeywell DR4500 Truline Relay Expansion Model User Manual Honeywell DR45AR Truline Relay Expansion Model Recorder User Manual
Honeywell DR4500 Modbus RTU Serial Communications Interface Manual Honeywell DR4500 Modbus RTU Serial Communications Interface Manual
How to replace a DR4500 latch and lock assembly Upgrade/Replacement: DR4500 Latch and Lock Assembly
How to replace a DR4500 pen arm assembly Upgrade/Replacement: DR4500 Pen Arm Assembly Kit
How to replace a DR4500 chart hub kit Upgrade/Replacement: DR4500 Chart Hub Kit