Which Regulator is Right for Your Application?

Operation Size Range Setpoints Flow Cv Control
Mechanism
Type Key Feature Regulator Series
Pressure
Reducing
1/4" to 1/2" 5 to 750 PSI 0.012 to 0.2   Self-operating High pressure, low flow requirements Lowflow JR Series
1/4" to 4" 2 to 290 PSI 0.21 to 19 Globe style Self-operating   Jordan Valve Mark 68G
1/4" to 4" 2 to 450 PSI 0.21 to 30 Sliding gate Self-operating All-around service Jordan Valve Mark 60
1/2" and 3/4" 5 to 125 PSI 0.5 to 0.8   Self-operating For high purity gas applications Steriflow JSR Series
1/2", 3/4",
and 1"
0 to 150 PSI 1.5 or 1.9   Diaphragm-operated For high flow, low control pressures LowFlow JRHF Series
1/2" to 6" 1 to 500 PSI 0.21 to 395 Sliding gate Air-loaded Connects to DCS Jordan Valve Mark 66
1/2" to 6" 10 to 200 PSI 2.5 to 50 Sliding gate Piloted 1-5% offset Jordan Valve Mark 67
3/4" to 3" 5 to 135 PSI 1.5 to 23   Self-operating For sanitary, clean-in-place and steam-in-place use Steriflow Mark 96
Back Pressure Reducing 1/2" 0 to 400 PSI 1.95   Diaphragm-operated For high flow, low control pressures LowFlow JBDL Series
1/2" to 1" 3 to 5800 PSI 0.5   Piston-operating For high flow, high pressure applications Lowflow JBPH Series
1/2" to 3" 3 to 60 PSI 0.5 to 28   Self-operating For sanitary, clean-in-place and steam-in-place use Steriflow Mark 95
Temperature 1/2" to 2" -20° to 450° F 0.0008 to 30 Sliding gate Self-operating Accuracy to ±3° F Jordan Valve Mark 80
1/2" to 4" 0.5 to 450 PSI 0.84 to 200 Sliding gate Self-operating For high viscosity liquids   Jordan Valve Mark 50