Which Radar Level Transmitter Fits Your Application?
Is your current contacting level technology undependable, unreliable, or maintenance-intensive? Do steam and vapors affect the accuracy and dependability of your existing level device? Do tanks and silos with coned bottoms cause problems getting reliable low level measurements?
Siemens radar technology has the cure for your level headaches. Reliable liquid and bulk solid level measurements, unaffected by steam and vapor. Narrow beam angle radars that provide strong level signals, even in tanks and silos with coned bottoms. Dynamic TVT thresholds that adjust depending on signal strength to reduce Loss-of-Echo errors. Process Intelligence quick start, easy menus, and step-by-step tuning, so you can configure your transmitter in as few as two parameters and less than five minutes — and reprogram the unit without a factory guy if your needs change. All of this and more, for anything from simple liquid storage tanks to dry solids and tall tanks, with prices starting under $1000.
Compare Siemens liquid level radar instruments
Model |
SITRANS Probe LR |
SITRANS LR200 |
SITRANS LR250 |
SITRANS LR400 |
SITRANS LG200 |
---|---|---|---|---|---|
Media | Liquids | Liquids and Slurries | Liquids, Slurries,
and Interfaces | ||
Frequency | 6.3 GHz pulse radar | 25 GHz pulse radar | 24 GHz FMCW radar | Guided wave radar | |
Range | 1 to 66 feet (0.3 to 20 meters) | 2" to 66 feet
(0.5 to 20 meters) | 1.15 to 164 feet (0.35 to 50 meters) | 0.5 to 75 feet (0.15 to 22.5 meters) | |
Antenna | Rod standard; Horn available, purge optional | Horn | Horn | 16 different probes available | |
Process Temp. | -40° to 176°F | -40° to 392°F | -40° to 320°F | -40° to 382°F | -320° to 800°F |
Process Pressure | 43.5 PSI max. | 580 PSI max. | Full vacuum to 6250 PSI max. | ||
Dielectric Constant | >3 (for <3 use waveguide antenna or stillpipe | >1.6 (depends on horn and use) | >1.6 | Liquids >1.4 to Liquids/slurries >10 | |
Accuracy | ±Greater of 0.1% range or 10mm | ±0.02 mA | ≤ 5mm at 2m to 10m, ≤15mm at 10m to 50m | To 2.5mm (0.1") | |
Output | 4-20 mA, HART | 4-20 mA, HART or Profibus PA,
NE 21, NE 43 | 4-20 mA, HART or Profibus PA, 1 relay | 4-20 mA, HART | |
Communi- cations | HART, SIMATIC PDM, Siemens infrared handheld | HART, Profibus PA, SIMATIC PDM, Siemens infrared handheld | HART, SIMATIC PDM, Siemens infrared handheld | ||
Process Connection | Threaded, flanged, and sanitary | Threaded or flanged | Flanged | Threaded or flanged | |
Local Display | Multi-segment alphanumeric LCD with bar graph | Graphical interface, with quick-start wizard and echo profile display | Alphanumeric LCD for readout and entry | ||
Enclosure | PBT polymer plastic, Type 4X/NEMA 4X, Type 6/IP68 | Aluminum, Type 4X/NEMA 4X, NEMA 6/IP67 | Aluminum, Type 4X, NEMA 4X, Type 6, NEMA 6, IP67, IP68 | Aluminum, Type 4X, NEMA 4X, IP67, Type 6/NEMA 6 | Epoxy-coated aluminum, Type 4, NEMA 4, IP65 |
Approvals | CE, CSA, FM, ATEX | CE, CSA, FM | CSA, CE, FM, ATEX | CSA, CE, FM, 3A, ATEX |
Compare Siemens solids level radar instruments
Model |
SITRANS LR260 | SITRANS LR460 |
SITRANS LR560 |
---|---|---|---|
Media | Solids | Solids | Solids |
Frequency | 25 GHz pulse radar | 24.2 to 25.2 GHz FMCW radar | 78 GHz FMCW radar |
Range | 2" to 98 feet (0.05 to 30 meters) | 1.15 to 328 feet (0.35 to 100 meters) | 15.75" to 328 feet (0.4 to 100 meters) |
Antenna | 2", 3", or 4" diameter horn, optional dust cover and purge connection | 3" or 4" diameter horn, optional dust cover and purge connection | Lens antenna, highly resistant to product buidup, with built-in air purge connection |
Process Temp. | -40° to 392°F | -40° to 392°F | -40° to 392°F |
Process Pressure | 7.25 PSI (0.5 bar) max. | 7.25 PSI (0.5 bar) max. | 43.5 PSI (3 bar) max. |
Dielectric Constant | >1.6 | >1.4 | >2.0 |
Accuracy | 1" (25mm) from minimum detectable distance to 11.8" (300mm); Rest of range: Greater of 0.4" (10mm) or 0.1% span | Greater of 1" (25mm) or 0.25% span, non-repeatability ≤0.4" (10mm) | Greater of 1" (25mm) or 0.25% across full range (includes hysteresis and non-repeatability) |
Analog Output | 4-20 mA loop powered | 4-20 mA optically isolated | 4-20 mA |
Communications and Programming | HART, Profibus PA, SIMATIC PDM, intrinsically safe handheld programmer, local operation | HART, Profibus PA, SIMATIC PDM, intrinsically safe handheld programmer, local operation | HART communicator, SIMATIC PDM, AMS, PACTware, intrinsically safe handheld programmer, or local user interface |
Process Connections | Universal: 2", 3", 4", or 6" with integral EasyAimer | Universal: 3", 4", or 6" with integral EasyAimer | Universal flat-faced flanges or Aimer flanges (3", 4", and 6" sizes) |
Local Display | Graphic LCD with bargraph and echo profile | Alphanumeric LCD | Grapic LCD with bar graph representing level |
Enclosure | Polyester powder-coated aluminum, Type 4X/NEMA 4X, Type 6/NEMA 6, IP67, IP68 | Polyester powder-coated aluminum, Type 4X/NEMA 4X, Type 6/NEMA 6, IP67, IP68 | 316L stainless steel, Type 4X/NEMA 4X, Type 6/NEMA 6, IP68 with lid closed |
Approvals | CSA, CE, FM, ATEX | CSA, CE, FM, ATEX | CSA, CE, FM, ATEX |